Local save ready
ServiceIQ
Field diagnostics
Checking
CURRENT CALL

No active call

Start a new call to begin.
StatusOpen Next stepEnter the complaint and equipment.
Current Call ProgressNot started
AirflowPending
ElectricalPending
RefrigerantPending
DiagnosisOpen

New Call

The first screen captures only what changes the diagnostic path.
Diagnostic setup
Conditions

TechSec Guided Diagnosis

Direct, technician-focused and one useful question at a time.
No active call

Active Call

Flow
Complaint
Equipment
Fault
StatusWaiting to begin
0% complete
STEP 0
Start a service call first
Enter the complaint, equipment and diagnostic flow, then launch TechSec.

Reference & Reasoning

ServiceTechIQ logic

Manufacturer information will appear here when the selected equipment and fault match a knowledge pack.

TechSec will explain why a test matters without burying the technician in unnecessary detail.

Safety rule
ServiceTechIQ never instructs a technician to permanently bypass a safety device.

Readings & Calculators

Enter the applicable measurements, then let TechSec review the complete set.

Analyze the entered readings

TechSec flags abnormal values, enforces Airflow Before Charge, ranks issues, and recommends the next separating test.
TESP uses the absolute value of return static plus supply static.
Initial refrigerant snapshotPT data v1.0.1
Overrides are marked in the report; raw inputs stay saved.
Generic wet-bulb/dry-bulb screening only. Manufacturer charging data controls.
Select a refrigerant, then enter pressure and line temperature.
Enter rated and measured HERM values.
Enter rated and measured FAN values.
ServiceTechIQ marks a capacitor failed when the measured capacitance is more than 6% above or below its rated µF. The voltage rating is recorded separately.
Compression Ratio
Uses absolute pressure: discharge PSIA ÷ suction PSIA.
Sensible, Latent & Total Capacity
Enter CFM plus return and supply dry-bulb/wet-bulb measurements.
Capacitor Under Load
Live-voltage test: Qualified technicians only. Use properly rated PPE and test equipment. Follow company and manufacturer safety procedures.
At 60 Hz, µF ≈ amps × 2652 ÷ volts.
Final refrigerant snapshot
Enter final pressures and line temperatures to calculate final SH/SC.
Proof rule: A blower motor is confirmed failed only after valid demand, correct motor line voltage, the correct motor command, intact harnesses, and free mechanical rotation are documented.
Select the motor architecture to display the required command test.
Functional and performance verification are tracked separately.

TechSec Reading Analysis

Review all entered readings together, rank the issues, and select the next separating test.
Waiting for readings
Enter the applicable readings above, then press Analyze. Blank fields are allowed—TechSec will identify important missing evidence.

Automatic Service Report

Built from the intake, tests, findings, repair and final verification.
No active report yet.

Report Completeness

Run the check before finishing the call.

Backup & Sync

StatusSaved Locally
Last local save
Last syncNot synced

Was TechSec helpful on this call?

Diagnostic Flows

Choose a master flow, then complete the call intake.

Fault Code Lookup

Search the offline fault library and send a result directly into a new call.

Manuals & Reference

Manufacturer references, offline PT charts, fault data, and field lookup tools.
Refrigerant PT Charts
Select a refrigerant or open this chart from an active call.
Temp °FBubble PSIGDew PSIG
Knowledge pack ready

Amana S-Series Outdoor

R-410A S-Series and Enhanced Capacity outdoor-unit service reference.

Communication • Startup • Charging • Airflow • Wiring • Troubleshooting
Communication: pages 20–22
Startup and charging: pages 18–30
Operation and airflow: pages 30–32
Wiring: pages 33–38
Troubleshooting: pages 43–47
Mode display: page 48 onward
7-segment display: page 54 onward
Startup checklist: page 58
Knowledge pack ready

Amana AHVE Air Handler

AHVE installation, operation, airflow, heat-kit and troubleshooting reference.

PCB • Fault recall • Network • Faults • Heat kits • Wiring
PCB diagram: page 14
Fault recall: pages 16–17
Network troubleshooting: pages 18–19
Fault codes: pages 20–22
Wiring diagram: page 25
Startup checklist: page 27
Knowledge pack ready

Carrier 27VNA0 Infinity

Variable-speed R-454B heat-pump installation, charging, component and diagnostic reference.

Charging • PCM/VFD • Sensors • Compressor • Fan • 125 code entries
Start-up and charging: pages 8-13
Major components: pages 15-18
Troubleshooting and sensors: pages 19-21
Diagnostic code table: page 22
Malfunction lockouts: page 23
Knowledge pack ready

Carrier FE5B Fan Coil

Communicating R-454B fan-coil airflow, A2L dissipation, ECM and status-code reference.

350 CFM/ton • A2L Dissipation • ECM • Communication • Status Codes
Leak dissipation system: pages 10-12
Start-up and LED operation: pages 13-14
ECM and fan-coil troubleshooting: pages 14-16
Airflow delivery charts: page 17 onward

For browser security, a local PDF must be linked again after closing the prototype. The embedded page references remain available offline.

Permissions & Privacy

ServiceTechIQ asks only when a technician chooses a feature that needs access.

🎙️ MicrophoneNot Enabled

Used only while TechSec Voice or local speech capture is active.

A microphone indicator is controlled by the phone or browser while access is active.

🔔 NotificationsNot Enabled

Reserved for future assigned-call alerts, reminders, and completed-report updates.

On iPhone and iPad, ServiceTechIQ must be installed on the Home Screen before web push can be enabled.

ᛒ Bluetooth DevicesComing Soon

Future support for compatible probes and field tools. No Bluetooth request is made in this build.

ServiceTechIQ will request device access only after the technician taps Connect Device.

📈 Usage AnalyticsOff

Optional app-performance and feature-usage information. It is not required to use ServiceTechIQ.

The current field beta does not transmit analytics; this setting stores your preference for the future app build.

📍 Location ServicesNot Enabled

ServiceTechIQ does not request location in this build. A future job-site feature must explain its purpose before asking.

App Health & Version

Connection, offline data, build versions, and troubleshooting information.

Build

ServiceTechIQv8.7 Field RC
UI build8.7.0-rc1
Diagnostic rules1.5
PT data1.0.1 official-core
Cachev8-7-rc1-cache-1

Live Status

NetworkChecking
TechSec APIChecking
API version
Offline app dataAvailable
Installed appChecking
Last syncNever

Demo & Training

Practice without mixing training data into production calls or reports.
Training isolation: Cases started here are labeled TRAINING and cannot sync as customer service reports.
Training controls
Select a scenario to begin.

Saved Cases

Resume, review, duplicate, export or delete locally saved service calls.

Unified Field Diagnosis

Airflow, electrical and refrigeration—one fast field workflow.
ABC logic active
Call setup

🌬 Airflow Not checked

Target CFM and TESP calculate automatically.

⚡ Electrical Not checked

Capacitors are evaluated against a ±6% tolerance.

❄ Refrigeration Not checked

SH/SC drive pattern severity; pressures add evidence.

ServiceTechIQ Analysis

Waiting for data
Enter what you measured. Blank fields are allowed—ServiceTechIQ will identify the highest-value missing test.

TechSec Voice

TechSec AI voice with Mason, plus local transcript parsing and diagnostic logic.
Checking voice systems

TechSec AI Voice

Backend: https://serviceiq-api.bushtodd1.workers.dev
Disconnected
Connect before using hold-to-talk. After connection, hold the round microphone while speaking and release when finished. Mason will answer through the phone speaker.
Security: the permanent OpenAI key stays inside the Cloudflare Worker secret. This page sends only a WebRTC offer to the ServiceTechIQ API.

Local speech-to-fields fallback

Use this microphone when AI voice is offline, or type below.
AI and local transcripts appear here. Review them before applying readings.

Mason Response

Connect TechSec Voice and hold the microphone to begin. ServiceTechIQ local diagnostic analysis remains available offline.
Field-test beta
AI voice requires internet access and OpenAI API billing. Calculators, saved cases, reports, and the local diagnostic engine remain available without the AI connection.

Airflow Diagnostic Engine

ABC Logic: Airflow Before Charge

System Information